Sistema de puerta pivotante: guía de peso y apertura
10:03
Allen Wang | CEO y fundador, HIPAD Updated: October 19, 2026
A pivot door system needs approval as an installed assembly, not by a headline weight alone. HIPAD’s supplied Door Controls reference lists pivot systems up to 200 kg with a 180-degree opening reference. Those figures help shortlist the family; they do not establish the rating, floor anchorage or achievable opening of every model in every entrance.
Solicite el modelo exacto de pivote y el plano de instalación antes de aplicar un rango a nivel de familia.
Published door-control ranges
HIPAD’s Door Controls product reference includes the following family descriptions. They are selection references, not a substitute for model-specific test documents or structural approval.
Control family
Published door-weight reference
Published opening reference
Primary question before selection
Pivot system
Hasta 200 kg
180 degrees
¿Pueden funcionar juntos el pivote elegido, la puerta y la estructura de suelo/cabezal?
Floor spring
Hasta 150 kg
180 degrees
Is closing control required, and is the floor condition suitable?
Cierrapuertas
60-120 kg
120-180 degrees
¿El cierrapuertas seleccionado se adapta a la puerta y a las exigencias de cierre?
Herraje de parche de acero inoxidable
No numerical range stated
No se indica ángulo
¿Está especificada la interfaz del vidrio y el herraje para el conjunto?
These are different functions and are not interchangeable solely because their published angles overlap. A pivot defines the rotation support; closing behavior and glass attachment may require other compatible components. Review the gama Door Controls como un sistema y, a continuación, solicite los planos exactos y la documentación justificativa de cada componente seleccionado.
Pivot door system load: what “up to 200 kg” leaves unanswered
Door mass is only one input. Give the supplier the door height, width, thickness, material, glazing arrangement and the pivot’s offset from the door edge. A wide leaf changes the operating geometry and loading at its supports even when its mass is unchanged. Ask for the proposed model’s declared door-size limits, fixings and installation conditions instead of treating the family maximum as an approval for a particular entrance.
Also identify whether the system is intended for a single leaf, a paired entrance or a replacement retrofit. In a retrofit, concealed services, finished flooring and existing recesses may constrain the pivot location. Do not choose a pivot solely because another site used a door of similar weight; that comparison omits the floor and head construction.
A floor spring is a separate control family; compare its function and installation conditions.
Opening angle must be measured in the entrance
La referencia de pivote de 180 grados no garantiza que cada hoja instalada alcance media vuelta completa. Los retornos de pared, el acristalamiento adyacente, las manillas, los topes, los acabados del suelo y el desplazamiento del pivote seleccionado pueden reducir el ángulo utilizable. Confirme el hueco libre de paso requerido en la tabla de puertas y, a continuación, pruebe un conjunto representativo de producción a lo largo de todo su recorrido. Compruebe la holgura de barrido, el contacto en los bordes y las interferencias de los herrajes en posiciones intermedias, no solo en apertura total.
If the project needs self-closing or controlled closing, define that requirement separately. A guía de selección de cierrapuertas explica por qué las referencias de peso y ángulo deben comprobarse con respecto a la geometría real de apertura. No dé por sentado que todos los sistemas pivotantes incluyen un cierrapuertas.
Floor support, fixing and glass interface
Ask the project engineer to identify the supporting substrate, finished floor build-up, recess depth, waterproofing and available fixing zones. The supplied HIPAD reference does not give one universal anchor design or floor-load calculation. Any fixing schedule must therefore be approved for the actual structure and the quoted model. Keep the upper support and door-leaf preparation in the same drawing set so their axes can be checked together.
For a glass entrance, verify the glass preparation and fitting interface against the chosen patch fitting. HIPAD’s supplied catalog lists stainless-steel patch fittings but does not publish a single numerical capacity for that family. A picture of a fitting cannot establish glass thickness, hole geometry or compatibility; request the model drawing and required glass specification.
El mecanizado del vidrio y la geometría del herraje requieren la especificación exacta de la pieza.
Five sample-approval checks for OEM buyers
Envíe los planos de la puerta y la entrada que muestren masa, dimensiones, desplazamiento del pivote, secciones de suelo y cabezal, sentido de apertura y hueco libre de paso objetivo.
Request the exact pivot model drawing, rated application conditions, fasteners and any relevant test evidence. Compare them with the family reference rather than copying it into a purchase order.
Compruebe el cajeado en el suelo, las zonas de anclaje, la cota de suelo terminado, la alineación del soporte superior y el acceso para la instalación o el mantenimiento posterior.
Instale una muestra representativa, mida su ángulo de apertura y holguras reales, y verifique si se requiere algún tope o control de cierre independiente.
Freeze the approved drawing revision, materials, finish, inspection points and packaging before repeat production.
HIPAD describes OEM/ODM support for custom drawings, structure and packaging. For a broader supplier review, use the door hardware manufacturer checklist. El material de origen no revela los precios del sistema pivotante ni los números de certificado a nivel de producto; solicite un presupuesto y la documentación para el modelo definido.
Preguntas frecuentes
Does “up to 200 kg” mean any 200 kg door can use the system?
No. Es una referencia publicada para la familia de productos. El modelo elegido debe verificarse con respecto a la geometría de la puerta, las condiciones de fijación y los límites a nivel de modelo del proveedor.
Does the pivot system automatically close the door?
No lo dé por sentado. Especifique el comportamiento de cierre requerido y confirme los componentes de control compatibles para el conjunto ofrecido.
Can the door always open 180 degrees?
No. El ángulo tras la instalación depende del desplazamiento del pivote, de la construcción adyacente y de los herrajes. Verifíquelo en un acceso representativo.
What if the finished floor has limited depth?
Incluya la sección del suelo en la consulta. El modelo propuesto, el cajeado y el esquema de fijación deben aprobarse para la obra real antes de realizar el pedido.
Para planificar una muestra OEM o solicitar un presupuesto específico para un modelo, póngase en contacto con HIPAD with the door schedule, floor/head details and opening requirement. If the entrance uses heavy hinges elsewhere, the guía de bisagras helps keep those separate hardware decisions explicit.
Sobre el autor: Allen Wang es director ejecutivo y fundador de HIPAD. Su trayectoria facilitada describe una experiencia de fabricación que comenzó en 1998 con la producción de rodamientos en Qingdao y el trabajo con compradores internacionales de herrajes para puertas y ventanas. Esta guía utiliza la referencia de la familia Door Controls de HIPAD; las especificaciones de un proyecto aún requieren documentación a nivel de modelo y la revisión de la instalación.
Responderemos en un plazo de 24 horas. Para solicitudes urgentes, contáctenos por WhatsApp/WeChat al +86 137 9191 8989 o llame directamente al mismo número.
*Respetamos la confidencialidad de sus datos y protegemos toda la información.
Solo utilizaremos su información para responder a su consulta y nunca enviaremos correos electrónicos ni mensajes promocionales no solicitados.